1.
J Clin Med ; 13(6)2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38541858

RESUMEN

Background: Scientific literature lacks strong support for using narrow diameter implants (NDI) in high masticatory force areas, especially in molars. Implant splinting in cases of multiple missing teeth reduces lateral forces, improves force distribution, and minimizes stress on implants. However, no studies have evaluated the fatigue load resistance of unitary or splinted implants. Methods: This in vitro study compares five groups of new metal alloy implants, including unitary and splinted implants with varying diameters. Mechanical characterization was assessed using a BIONIX 370 testing machine (MTS, Minneapolis, MN, USA) according to ISO 14801. For each of the five study sample groups, (n = 5) specimens underwent monotonic uniaxial compression at break testing and (n = 15) cyclic loading to determine the maximum force (Fmax) and the fatigue life (LF) values. Scanning electron microscopy (SEM) was employed for the fractographic analysis of the fractured samples. Results: The Fmax values for unitary samples ranged from 196 N to 246 N, whereas the two-splinted samples displayed significantly higher values, ranging from 2439 N to 3796 N. Similarly, the LF values for unitary samples ranged from 118 N to 230 N, while the two-splinted samples exhibited notably higher values, ranging from 488 N to 759 N. Conclusions: The observed resistance difference between sample groups in terms of Fmax and LF may be due to variations in effective cross-sectional area, determined by implant diameter and number. Additionally, this disparity may indicate a potential stiffening effect resulting from the splinting process. These findings have significant implications for dental clinical practice, suggesting the potential use of splinted sets of small-sized NDI as replacements for posterior dentition (premolars and molars) in cases of alveolar bone ridge deficiencies.

2.
Polymers (Basel) ; 16(5)2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38475352

RESUMEN

Soft tissue defects, such as incisional hernia or pelvic organ prolapse, are prevalent pathologies characterized by a tissue microenvironment rich in fragile and dysfunctional fibroblasts. Precision medicine could improve their surgical repair, currently based on polymeric materials. Nonetheless, biomaterial-triggered interventions need first a better understanding of the cell-material interfaces that truly consider the patients' biology. Few tools are available to study the interactions between polymers and dysfunctional soft tissue cells in vitro. Here, we propose polypropylene (PP) as a matrix to create microscale surfaces w/wo functionalization with an HBII-RGD molecule, a fibronectin fragment modified to include an RGD sequence for promoting cell attachment and differentiation. Metal mold surfaces were roughened by shot blasting with aluminum oxide, and polypropylene plates were obtained by injection molding. HBII-RGD was covalently attached by silanization. As a proof of concept, primary abdominal and vaginal wall fasciae fibroblasts from control patients were grown on the new surfaces. Tissue-specific significant differences in cell morphology, early adhesion and cytoskeletal structure were observed. Roughness and biofunctionalization parameters exerted unique and combinatorial effects that need further investigation. We conclude that the proposed model is effective and provides a new framework to inform the design of smart materials for the treatment of clinically compromised tissues.

3.
J Funct Biomater ; 14(2)2023 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-36826866

RESUMEN

Digital dentistry and new techniques for the dental protheses' suprastructure fabrication have undergone a great evolution in recent years, revolutionizing the quality of dental prostheses. The aim of this work is to determine whether the best horizontal marginal fit is provided by the CAD-CAM technique or by laser sintering. These values have been compared with the traditional casting technique. A total of 30 CAD-CAM models, 30 laser sintering models, and 10 casting models (as control) were fabricated. The structures realized with chromium-cobalt (CrCo) have been made by six different companies, always with the same model. Scanning electron microscopy with a high-precision image analysis system was used, and 10,000 measurements were taken for each model on the gingival (external) and palatal (internal) side. Thus, a total of 1,400,000 images were measured. It was determined that the CAD-CAM technique is the one that allows the best adjustments in the manufacturing methods studied. The laser sintering technique presents less adjustment, showing the presence of porosities and volume contraction defects due to solidification processes and heterogeneities in the chemical composition (coring). The technique with the worst adjustments is the casting technique, containing numerous defects in the suprastructure. The statistical analysis of results reflected the presence of statistically significant gap differences between the three manufacturing methods analyzed (p < 0.05), with the samples manufactured by CAD-CAM and by traditional casting processes being the ones that showed lower and higher values, respectively. No statistically significant differences in fit were observed between the palatal and gingival fit values, regardless of the manufacturing method used. No statistically significant differences in adjustment between the different manufacturing centers were found, regardless of the process used.

4.
Materials (Basel) ; 15(20)2022 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-36295241

RESUMEN

Present commercial titanium alloy implants have an elastic modulus higher than 100 GPa, whereas that of the cortical bone is much smaller (17−28 GPa). This elastic modulus mismatch produces a stress shielding effect and the resorption of the bone surrounding the implant. In the present work, a <100> fiber texture is developed in ß type Ti-42Nb (wt%) alloy ingots generated by laser-directed energy deposition (LDED) in order to achieve anisotropic mechanical properties. In addition, we demonstrate that laser-deposited ß type Ti-42Nb alloy ingots with an intense <100> fiber texture exhibit a very low elastic modulus in the building direction (Ez < 50 GPa) and high yield (σ0.2z > 700 MPa) and tensile (UTSz > 700 MPa) strengths. Laser-deposited Ti-42Nb alloy enhances the osteoinductive effect, promoting the adhesion, proliferation, and spreading of human osteoblast-like cells. Hence, we propose that laser-deposited ß type Ti-42Nb alloy is a potentially promising candidate for the manufacturing of pioneering biomedical implants with a very low elastic modulus that can suppress stress shielding.

5.
Materials (Basel) ; 15(15)2022 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-35955326

RESUMEN

The use of a PMMA composite with graphene is being commercialized for application as dental prostheses. The different proportions of fibers provide a wide range of colors that favors dental esthetics in prostheses. However, there are no studies that have explained the influence that graphene has on the mechanical properties. In this contribution, we studied the PMMA and PMMA material with graphene fibers (PMMA-G) in the form of discs as supplied for machining. The presence of graphene fibers has been studied by Raman spectroscopy and the Shore hardness and Vickers micro hardness were determined. Mechanical compression tests were carried out to obtain the values of maximum strength and Young's modulus (E) and by means of pin-on-disc wear tests, the specific wear rate and the friction coefficients were determined following the established international standards. Finally, the samples were characterized by field emission scanning electron microscopy (FESEM) to characterize the graphene's morphology inside the PMMA. The results showed the presence of graphene in PMMA and was estimated in an amount of 0.1027% by weight in G-PMMA. The Shore hardness and Vickers microhardness values did not show statistically significant differences. Differences were observed in the compression maximum strength (129.43 MPa for PMMA and 140.23 for PMMA-G) and E values (2.01 for PMMA and 2.89 GPa for PMMA-G) as well as in the lower wear rate for the G-PMMA samples (1.93 × 10−7 for PMMA and 1.33 × 10−7 mm3/N·m) with a p < 0.005. The coefficients of friction for PMMA-G decreased from 0.4032 for PMMA to 0.4001 for PMMA-G. From the results obtained, a slight content in graphene produced a significant improvement in the mechanical properties that could be observed in the prosthesis material. Therefore, we can state that the main attraction of this material for dental prosthesis is its esthetics.

6.
Int J Mol Sci ; 23(3)2022 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-35163682

RESUMEN

A lack of primary stability and osteointegration in metallic implants may result in implant loosening and failure. Adding porosity to metallic implants reduces the stress shielding effect and improves implant performance, allowing the surrounding bone tissue to grow into the scaffold. However, a bioactive surface is needed to stimulate implant osteointegration and improve mechanical stability. In this study, porous titanium implants were produced via powder sintering to create different porous diameters and open interconnectivity. Two strategies were used to generate a bioactive surface on the metallic foams: (1) an inorganic alkali thermochemical treatment, (2) grafting a cell adhesive tripeptide (RGD). RGD peptides exhibit an affinity for integrins expressed by osteoblasts, and have been reported to improve osteoblast adhesion, whereas the thermochemical treatment is known to improve titanium implant osseointegration upon implantation. Bioactivated scaffolds and control samples were implanted into the tibiae of rabbits to analyze the effect of these two strategies in vivo regarding bone tissue regeneration through interconnected porosity. Histomorphometric evaluation was performed at 4 and 12 weeks after implantation. Bone-to-implant contact (BIC) and bone in-growth and on-growth were evaluated in different regions of interest (ROIs) inside and outside the implant. The results of this study show that after a long-term postoperative period, the RGD-coated samples presented higher quantification values of quantified newly formed bone tissue in the implant's outer area. However, the total analyzed bone in-growth was observed to be slightly greater in the scaffolds treated with alkali thermochemical treatment. These results suggest that both strategies contribute to enhancing porous metallic implant stability and osteointegration, and a combination of both strategies might be worth pursuing.


Asunto(s)
Álcalis/farmacología , Materiales Biocompatibles Revestidos/farmacología , Metalurgia , Oligopéptidos/farmacología , Oseointegración , Temperatura , Andamios del Tejido/química , Titanio/farmacología , Animales , Femenino , Implantes Experimentales , Oseointegración/efectos de los fármacos , Osteogénesis/efectos de los fármacos , Porosidad , Polvos , Conejos
7.
Materials (Basel) ; 15(2)2022 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-35057263

RESUMEN

The passivation of titanium dental implants is performed in order to clean the surface and obtain a thin layer of protective oxide (TiO2) on the surface of the material in order to improve its behavior against corrosion and prevent the release of ions into the physiological environment. The most common chemical agent for the passivation process is hydrochloric acid (HCl), and in this work we intend to determine the capacity of citric acid as a passivating and bactericidal agent. Discs of commercially pure titanium (c.p.Ti) grade 4 were used with different treatments: control (Ctr), passivated by HCl, passivated by citric acid at 20% at different immersion times (20, 30, and 40 min) and a higher concentration of citric acid (40%) for 20 min. Physical-chemical characterization of all of the treated surfaces has been carried out by scanning electronic microscopy (SEM), confocal microscopy, and the 'Sessile Drop' technique in order to obtain information about different parameters (topography, elemental composition, roughness, wettability, and surface energy) that are relevant to understand the biological response of the material. In order to evaluate the corrosion behavior of the different treatments under physiological conditions, open circuit potential and potentiodynamic tests have been carried out. Additionally, ion release tests were realized by means of ICP-MS. The antibacterial behavior has been evaluated by performing bacterial adhesion tests, in which two strains have been used: Pseudomonas aeruginosa (Gram-) and Streptococcus sanguinis (Gram+). After the adhesion test, a bacterial viability study has been carried out ('Life and Death') and the number of colony-forming units has been calculated with SEM images. The results obtained show that the passivation with citric acid improves the hydrophilic character, corrosion resistance, and presents a bactericide character in comparison with the HCl treatment. The increasing of citric acid concentration improves the bactericide effect but decreases the corrosion resistance parameters. Ion release levels at high citric acid concentrations increase very significantly. The effect of the immersion times studied do not present an effect on the properties.

8.
J Prosthet Dent ; 127(3): 470-476, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33309211

RESUMEN

STATEMENT OF PROBLEM: Polyetheretherketone (PEEK) has been advocated to replace metal components in dentistry. Although PEEK is a high-performance polymer with a white color, adequate biological response, and resistance to fracture, data to support PEEK as an alternative material for implant abutments are lacking. PURPOSE: The purpose of this in vitro study was to assess the mechanical and functional properties of PEEK implant abutments as a nonmetallic alternative to titanium abutments, which presents esthetic limitations and greater difficulty to customize clinically. MATERIAL AND METHODS: Implant abutments manufactured by using PEEK (n=24) or titanium grade 5 (n=24) were attached to MIS Implants type M4 3.75×16 mm with an internal screw tightened to 25 Ncm. Screw loosening and microleakage was assessed by submersion in a 2% methylene blue solution for 48 hours at 37 °C. Both groups were compared with and without applying dynamic loading; fatigue testing was performed following the International Organization for Standardization (ISO) 14801:2016 standard. All specimens were observed under a stereomicroscope at ×8 magnification. Statistically significant differences among the PEEK and titanium implant abutments were tested with 2-factor ANOVA and the chi-square analysis for nonpaired and paired data, respectively (α=.05). RESULTS: The implant abutments made of titanium were better in all mechanical tests. The torque loss of titanium abutments was approximately 10%, while PEEK showed a significantly higher (P<.05) torque loss of up to 50%. Moreover, 91.6% of the titanium abutments did not present microleakage, while there was no specimen of PEEK abutments without microleakage, once subjected to dynamic loading (P<.05). CONCLUSIONS: Titanium implant abutments (Ti6Al4V) were better in all tests performed. However, PEEK abutments may be suitable for long-term interim restorations, especially in the anterior area, in patients without parafunction.


Asunto(s)
Implantes Dentales , Titanio , Benzofenonas , Tornillos Óseos , Pilares Dentales , Diseño de Implante Dental-Pilar , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Estética Dental , Humanos , Ensayo de Materiales , Pruebas Mecánicas , Polímeros , Circonio
9.
Materials (Basel) ; 14(24)2021 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-34947480

RESUMEN

The present experimental trial uses two types of dental implants, one made of titanium (Ti6Al4V) and the other one of zirconia (ZrO2), but both of identical design, to compare their stability and micro-movements values under load. One of each type of implant (n = 42) was placed into 21 cow ribs, recording the insertion torque and the resonance frequency using a specific transducer. Subsequently, a prosthetic crown made of PMMA was screwed onto each of the implants in the sample. They were then subjected to a static compression load on the vestibular cusp of the crown. The resulting micromovements were measured. The zirconia implants obtained a higher mean of both IT and RFA when compared with those of titanium, with statistically significant differences in both cases (p = 0.0483 and p = 0.0296). However, the micromovement values when load was applied were very similar for both types, with the differences between them (p = 0.3867) not found to be statistically significant. The results show that zirconia implants have higher implant stability values than titanium implants. However, the fact that there are no differences in micromobility values implies that caution should be exercised when applying clinical protocols for zirconia based on RFA, which only has evidence for titanium.

10.
Materials (Basel) ; 13(23)2020 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-33255355

RESUMEN

Although ceramic-on-ceramic (CoC) bearings have been shown to produce the smallest amount of wear volume in vitro as well as in vivo studies when used for total hip arthroplasties (THA), concerns about the failure of these bearing surfaces persist due to early failures observed after short postoperative time. In this study, an exhaustive analysis of the early failure occurred on the new generation of ceramic bearings, consisting of a composite alumina matrix-based material reinforced with yttria-stabilized tetragonal zirconia (Y-TZP) particles, chromium dioxide, and strontium crystals, was performed. For this study, 118 CoC bearings from 117 patients were revised. This article describes a group of mechanical failure CoC-bearing BIOLOX THA hip prosthesis patients without trauma history. The retrieved samples were observed under scanning electron microscopy (SEM), composition was analyzed with energy dispersive X-ray spectroscopy (EDX), and damaged surfaces were analyzed by grazing-incidence X-ray diffraction (GI-XRD) and white light interferometry. In the short term, CoC articulations provided similar mechanical behavior and functional outcome to those in XLPE cases. However, 5% more early mechanical failures cases were observed for the ceramic components. Although the fracture rate of third generation CoC couples is low, the present study shows the need to further improve the third generation of CoC-bearing couples for THA. Despite the improved wear compared to other materials, stress concentrators are sources of initial crack propagation, such as those found in the bore-trunnion areas. Moreover, in view of the evidence observed in this study, the chipping observed was due to the presence of monoclinic phase of the Y-TZP instead of tetragonal, which presents better mechanical properties. The results showed that total safety after receiving a THA is still a goal to be pursued.

11.
Polymers (Basel) ; 12(4)2020 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-32244655

RESUMEN

Infections related to dental implants are a common complication that can ultimately lead to implant failure, and thereby carries significant health and economic costs. In order to ward off these infections, this paper explores the immobilization of triethoxysilylpropyl succinic anhydride (TESPSA, TSP) silane onto dental implants, and the interaction of two distinct monospecies biofilms and an oral plaque with the coated titanium samples. To this end, titanium disks from prior machining were first activated by a NaOH treatment and further functionalized with TESPSA silane. A porous sodium titanate surface was observed by scanning electron microscopy and X-ray photoelectron spectroscopy analyses confirmed the presence of TESPSA on the titanium samples (8.4% for Ti-N-TSP). Furthermore, a lactate dehydrogenase assay concluded that TESPSA did not have a negative effect on the viability of human fibroblasts. Importantly, the in vitro effect of modified surfaces against Streptococcus sanguinis, Lactobacillus salivarius and oral plaque were studied using a viable bacterial adhesion assay. A significant reduction was achieved in all cases but, as expected, with different effectiveness against simple mono-species biofilm (ratio dead/live of 0.4) and complete oral biofilm (ratio dead/live of 0.6). Nevertheless, this approach holds a great potential to provide dental implants with antimicrobial properties.

12.
Materials (Basel) ; 12(22)2019 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-31726659

RESUMEN

Sixty-four fractured commercially pure titanium (cp-Ti) narrow dental implants (NDIs) with similar macrogeometry and connection designs were studied after different implantation times in humans in order to determine their reliability and to evaluate the causes of the fracture. These NDIs were compared with other similar implants, made with alloyed titanium with 15% Zr and with 12% strained titanium. Original implants were tested under static and fatigue conditions, simulating the tri-axial loads in the mouth by means of a Bionix hydraulic test machine. Fractography was studied using field-emission scanning electron microscopy (FSEM). The results showed that cp-Ti NDI exhibits low strength for mechanical cycling, and the alloyed Ti and strained titanium increase the mechanical strength, guaranteeing long term mechanical behavior. NDIs fractured due to fatigue, and, in some cases, the presence of cracks in the original NDIs quickly led to fracture. These cracks were attributed to plastic deformation during machining were found to be exacerbated due to acid etching in the passivation process. All cases of fracture were cp-Ti dental implants due to the low fatigue limit. The results show that, when titanium is alloyed or cold-worked, the fatigue limit is higher than cp-Ti. This in vitro research will help clinicians to select a better NDI system for safer treatment.

13.
Colloids Surf B Biointerfaces ; 180: 245-253, 2019 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-31055151

RESUMEN

The lack of bioactivity of titanium (Ti) is one of the main drawbacks for its application in biomedical implants since it can considerable reduce its osseointegration capacities. One strategy to overcome this limitation is the coating of Ti with hydroxyapatite (HA), which presents similar chemical composition than bone. Nonetheless, most of the strategies currently used generate a non-stable coating and may produce the formation of amorphous phases when high temperatures are used. Herein, we proposed to generate a Ti-HA composite coating on Ti surface to improve the stability of the bioactive coating. The coating was produced by cold gas spraying, which uses relatively low temperatures, and compared to a Ti coating. The coating was thoroughly characterized in terms of morphology, roughness, porosity and phase composition. In addition, the coating was mechanically characterized using a tensile loading machine. Finally, biological response was evaluated after seeding SaOS-2 osteoblasts and measuring cell adhesion, proliferation and differentiation. The novel Ti-HA coating presented high porosity and high adhesion and bond strengths. No change in HA phases was observed after coating formation. Moreover, osteoblast-like cells adhered, proliferated and differentiated on Ti-HA coated surfaces suggesting that the novel coating might be a good candidate for biomedical applications.


Asunto(s)
Tecnología Biomédica/métodos , Materiales Biocompatibles Revestidos/química , Frío , Durapatita/química , Gases/química , Titanio/química , Línea Celular , Humanos , Osteoblastos/citología , Porosidad , Soluciones , Propiedades de Superficie , Resistencia a la Tracción , Difracción de Rayos X
14.
Int J Mol Sci ; 19(9)2018 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-30200178

RESUMEN

In this study, highly-interconnected porous titanium implants were produced by powder sintering with different porous diameters and open interconnectivity. The actual foams were produced using high cost technologies: Chemical Vapor Deposition (CVD), Physical Vapor Deposition (PVD), and spark plasma sintering, and the porosity and/or interconnection was not optimized. The aim was to generate a bioactive surface on foams using two different strategies, based on inorganic thermo-chemical treatment and organic coating by peptide adsorption, to enhance osseointegration. Porosity was produced using NaCl as a space holder and polyethyleneglicol as a binder phase. Static and fatigue tests were performed in order to determine mechanical behaviors. Surface bioactivation was performed using a thermo-chemical treatment or by chemical adsorption with peptides. Osteoblast-like cells were cultured and cytotoxicity was measured. Bioactivated scaffolds and a control were implanted in the tibiae of rabbits. Histomorphometric evaluation was performed at 4 weeks after implantation. Interconnected porosity was 53% with an average diameter of 210 µm and an elastic modulus of around 1 GPa with good mechanical properties. The samples presented cell survival values close to 100% of viability. Newly formed bone was observed inside macropores, through interconnected porosity, and on the implant surface. Successful bone colonization of inner structure (40%) suggested good osteoconductive capability of the implant. Bioactivated foams showed better results than non-treated ones, suggesting both bioactivation strategies induce osteointegration capability.


Asunto(s)
Materiales Biocompatibles Revestidos/química , Oseointegración/efectos de los fármacos , Osteoblastos/citología , Tibia/cirugía , Titanio/química , Adsorción , Animales , Supervivencia Celular , Células Cultivadas , Femenino , Porosidad , Prótesis e Implantes , Conejos , Estrés Mecánico , Propiedades de Superficie , Temperatura
15.
J Appl Biomater Funct Mater ; 16(2): 83-89, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28885666

RESUMEN

BACKGROUND: The topographical features on the surface of dental implants have been considered as a critical parameter for enhancing the osseointegration of implants. In this work, we proposed a surface obtained by a combination of shot blasting and double acid etching. The double acid etching was hypothesized to increase the submicron topography and hence further stimulate the biological properties of the titanium implant. METHODS: The topographical features (surface roughness and real surface area), wettability and surface chemical composition were analyzed. RESULTS: The results showed that the proposed method produced a dual roughness, mainly composed of randomly distributed peaks and valleys with a superimposed nanoroughness, and hence with an increased specific surface area. Despite the fact that the proposed method does not introduce significant chemical changes, this treatment combination slightly increased the amount of titanium available on the surface, reducing potential surface contaminants. Furthermore, the surface showed increased contact angle values demonstrating an enhanced hydrophobicity on the surface. The biological behavior of the implants was then assessed by culturing osteoblast-like cells on the surface, showing enhanced osteoblast adhesion, proliferation and differentiation on the novel surface. CONCLUSIONS: Based on these results, the described surface with dual roughness obtained by double acid etching may be a novel route to obtain key features on the surface to enhance the osseointegration of the implant. Our approach is a simple method to obtain a dual roughness that mimics the bone structure modified by osteoclasts and increases surface area, which enhances osseointegration of dental implants.


Asunto(s)
Grabado Dental/métodos , Implantes Dentales , Ensayo de Materiales , Oseointegración , Línea Celular Tumoral , Humanos , Humectabilidad
16.
J Arthroplasty ; 32(12): 3782-3795, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28754580

RESUMEN

BACKGROUND: Besides promising results of metal-on-metal (MOM) hip arthroplasty (HA), frequent failures have been reported even in the short term. Many host, surgical, design, metallurgical, and processing factors have been evoked in the base of these events. We have tried to characterize and to evaluate metallurgical and processing features present in this type of implants. METHODS: The acetabular and femoral components of 20 MOM HAs collected from a multicenter retrieval program were examined. All the specimens were inspected with naked eye, with confocal microscopy and vertical scanning interferometry, scanning electron microscopy, back-scattered electron imaging, and energy-dispersive X-ray spectroscopy, in 25 zones of each articular component. RESULTS: Gas pores, shrinkage voids and holes of detached carbides, carbides on surface, embedded particles, scratches and marks of wear, surface discoloration, surface deposits, and tribochemical reaction layers were widely dispersed through a substantial percentage of the total bearing surface in all the implanted components. Surface cup and head voids, and cup scratches showed significant correlation with the clearance of pair. A higher surface damage of the cup and head was observed mainly in the low clearance prostheses. There was no other significant correlation or difference in the incidence and importance of any of these defects between resurfacing hip arthroplasties and total hip arthroplasties, or according to the pair diameter. CONCLUSION: Some metallurgical features and surface damage were significantly present in the retrieved implants of MoM HAs. It would be desirable to improve the structure and metallurgical characteristics of these implants to avoid those effects and optimize their performance.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera , Fémur/cirugía , Prótesis de Cadera , Prótesis Articulares de Metal sobre Metal , Falla de Prótesis , Adulto , Anciano , Electrones , Femenino , Humanos , Interferometría , Masculino , Metales , Microscopía Confocal , Microscopía Electrónica de Rastreo , Persona de Mediana Edad , Diseño de Prótesis , Propiedades de Superficie